Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 132
Filtrar
1.
Sci Rep ; 12(1): 1189, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35075225

RESUMO

Although there are increasing reports on the usefulness of sonopalpation with ultrasound imaging, many previous studies have reported interventions without a control group. This single-blind, parallel-group randomised controlled trial aimed to determine whether educational instruction with sonopalpation for physical therapy students has a more superior effect on skill improvement than traditional instruction without ultrasonography. Twenty-nine physical therapy students participated in the study and were randomised using block randomisation into an ultrasound imaging group (n = 15) and a control group (n = 14). Subsequently, they underwent three training sessions focusing on the shoulder joint. Participants underwent a scoring assessment of their palpation skills at pre-intervention, post-intervention, and follow-up 3 months after training. The raters were blinded to the subjects' group. The Friedman and Mann-Whitney U tests were used for data analysis. The intervention group showed a significant increase in scores at post-intervention and the 3-month follow-up; the effect sizes were large (0.849 and 0.849, respectively). A comparison of the scores at different time points after the intervention at the 3-month follow-up revealed no significant difference between the groups. Education using ultrasound imaging may be non-inferior to education without it; nevertheless, further studies are needed to demonstrate superiority.


Assuntos
Palpação/normas , Modalidades de Fisioterapia/educação , Ultrassonografia , Humanos , Articulação do Ombro/diagnóstico por imagem
2.
Chiropr Man Therap ; 29(1): 20, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-34127016

RESUMO

OBJECTIVE: The objective of this study was to establish the level of inter-examiner reliability for six common cervical manual and physical examination procedures used to assess the cervical spine. MATERIALS: Reliability study that used a convenience sample of 51 patients between the ages of 16-70 years presenting with a chief complaint of neck pain. Two physical therapists independently performed the same series of cervical physical examination procedures on each of the participant. The clinicians were blinded to each other's findings and the clinical status of the patient. Kappa coefficients (κ) were calculated for levels of agreement between the clinicians for each procedure. RESULTS: When assessing for asymmetrical motion, excellent levels of reliability (κ range: 0.88-0.96) were observed for the Bilateral Modified Lateral Shear (asymmetry criterion), Bilateral C2 Spinous Kick (asymmetry criterion) and Flexion-Rotation Tests. When pain provocation was used as the indicator of a positive test during palpation of the cervical facet joints, moderate to substantial levels of reliability (κ range: 0.53-0.76) were observed. When patients were instructed not to provide feedback to the clinicians about pain provocation during facet joint palpation and clinicians relied solely on their qualitative assessment of segmental mobility, the level of reliability was lower (κ range: 0.45-0.53). Due to 100 % prevalence of negative findings, Kappa values could not be calculated for the Sharp-Purser test or the Unilateral C2 Spinous Kick Test. CONCLUSIONS: Most physical examination procedures examined in this study demonstrated moderate to excellent levels of inter-examiner reliability. Palpation for segmental mobility without pain provocation demonstrated a lower level of reliability compared to palpation for pain provocation. Correlation with clinical findings is necessary to establish validity and the applicability of these procedures in clinical practice.


Assuntos
Cervicalgia/fisiopatologia , Palpação/normas , Exame Físico/normas , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
3.
J Manipulative Physiol Ther ; 44(4): 307-318, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33896601

RESUMO

OBJECTIVE: The primary objective of this review was to investigate the reliability and validity of palpatory clinical tests of sacroiliac mobility. The secondary objective was to investigate which palpatory clinical tests of sacroiliac mobility exist in the literature. METHODS: PubMed, Embase, Scopus, Medline, and the Physiotherapy Evidence Database were searched. There was no restriction on the study design or participants. The data extracted from each study were sample size, study deign, and clinical test used. If there was information on reliability values, number of examiners, concurrent validity values, gold standard used, or inferential statistical test used, that was also extracted. For intraexaminer reliability, the data were expressed as κ values that were meta-analyzed using random effects. RESULTS: Fifteen palpatory clinical tests of sacroiliac mobility were identified from 28 studies; 14 studies performed inferential statistical analysis, all including analysis of interexaminer reliability, with κ values ranging from -0.05 to 0.77. Analysis of intraexaminer reliability was performed in 8 studies, with κ values ranging from 0.08 to 0.73. No study included in this systematic review verified the concurrent validity of the tests. Our meta-analysis of intraexaminer reliability showed moderate to good agreement results for the Gillet test (κ = 0.46), the standing flexion test (κ = 0.61), and the sitting flexion test (κ = 0.68). CONCLUSION: We found 15 palpatory clinical tests of sacroiliac mobility in this systematic review. According to our meta-analysis, only the sitting flexion test obtained a good and statistically significant intraexaminer agreement. Further studies are necessary to evaluate the reliability and validity of these tests.


Assuntos
Dor Lombar/diagnóstico , Palpação/normas , Exame Físico/normas , Articulação Sacroilíaca , Humanos , Modalidades de Fisioterapia/normas , Valores de Referência , Reprodutibilidade dos Testes
4.
Breast Dis ; 39(3-4): 127-135, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32831188

RESUMO

BACKGROUND AND AIM: Traditionally lumpectomy as a part of breast-conserving surgery (BCS) is performed by palpation-guided method leading to positive margins and large excision volumes. There is no evidence suggesting that wide margin excisions decrease intra-breast tumour recurrence. Various perioperative techniques are used for margin assessment. We aimed to compare three commonly used techniques, i.e., ultrasound-guided surgery, palpation-guided surgery and cavity shaving for attaining negative margins and estimating the extent of healthy breast tissue resection. METHOD: A prospective comparative study was performed on 90 patients who underwent breast conservation surgery for early breast cancer between August 2018 and June 2019. Tumour excision with a minimum of 1 cm margin was done either using ultrasound, palpation or cavity shaving. Histopathological evaluation was done to assess the margin status and excess amount of resected normal breast tissue. Calculated resection ratio (CRR) defining the excess amount of the resected breast tissue was achieved by dividing the total resection volume (TRV) by optimal resection volume (ORV). The time taken for excision was also recorded. RESULTS: Histopathology of all 90 patients (30 in each group) revealed a negative resection margin in 93.3% of 30 patients in palpation-guided surgery group and 100% in both ultrasound-guided surgery and cavity shaving groups. Two patients (6.7%) from the cavity shaving group had positive margins on initial lumpectomy but shave margins were negative. TRV was significantly less in the ultrasound-guided surgery group compared to the palpation-guided surgery group and cavity shaving group (76.9 cm3, 94.7 cm3 and 126.3 cm3 respectively; p < 0.0051). CRR was 1.2 in ultrasound group compared to 1.9 in palpation group and 2.1 in cavity shave group which was also statistically significant (p < 0.0001).Excision time was significantly less (p < 0.001) in palpation-guided surgery group (13.8 min) compared to cavity shaving group (15.1 min) and ultrasound-guided group (19.4 min). CONCLUSION: Ultrasound-guided surgery is more accurate in attaining negative margins with the removal of least amount of healthy breast tissue compared to palpation-guided surgery and cavity shaving.


Assuntos
Neoplasias da Mama/cirurgia , Mama/cirurgia , Mastectomia Segmentar/métodos , Palpação/normas , Ultrassonografia Mamária/normas , Adulto , Idoso , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Margens de Excisão , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Palpação/métodos , Estudos Prospectivos , Ultrassonografia Mamária/métodos
5.
Medicina (Kaunas) ; 56(2)2020 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-32085506

RESUMO

BACKGROUND AND OBJECTIVES: Palpation is an inherent and basic skill of health professionals-particularly manual therapists who base their diagnosis and treatment in a clinical environment. Many authors have previously described multiple palpation positions for supraspinatus muscle tendon (SMT); however, there are no current studies that evaluate palpation concordance reliability for the SMT in this particular position. This study aimed to investigate the intra- and inter-rater reliabilities of supraspinatus muscle tendon (SMT) palpation. MATERIALS AND METHODS: Thirty-six healthy participants (14 females; aged 22-35 years) were recruited. Musculoskeletal ultrasound was used to measure the SMT localization after two physiotherapists performed the SMT palpation at two different times. The distance between the two marked points was used to analyze the analysis of true agreement between examiners. Finally, we analyzed if the demographic variables influenced the palpation procedure. RESULTS: The intra-examiner reliability showed a high percentage of concordance for examiner 1 (E.1) (first palpation procedure (P.1) = 91.7%: second palpation procedure (P.2) = 95.8%) and examiner 2 (E.2) (P.1 = 91.6%; P.2 = 97.2%) and high percentage of inter-palpation agreement for E.1 (87.5%) and E.2 (88.9%). The inter-examiner reliability showed a high total concordance for the right shoulder (E.1 = 94.4%; E.2 = 95.8%) and left shoulder (E.1 = 93.05%; E.2 = 95.05%). The agreement (%) according to both examiners was 93.05% for the right shoulder and 94.4% for the left shoulder. The agreement between both examiners and the ultrasound (% of true agreement) was 92.9% for the right shoulder and 92.8% for the left shoulder. A statistically significant association (p = 0.02) was found for weight regarding concordance reliability; this was not seen for dominant arm, age, gender, body mass index, height, and tendon depth (p > 0.05). CONCLUSIONS: The SMT palpation technique showed a high level of concordance and reproducibility.


Assuntos
Variações Dependentes do Observador , Palpação/normas , Manguito Rotador/diagnóstico por imagem , Ultrassonografia/normas , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Palpação/métodos , Palpação/estatística & dados numéricos , Fisioterapeutas/normas , Fisioterapeutas/estatística & dados numéricos , Reprodutibilidade dos Testes , Manguito Rotador/fisiologia , Ultrassonografia/métodos , Ultrassonografia/estatística & dados numéricos
6.
Arch Dis Child Fetal Neonatal Ed ; 105(2): 196-200, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31248962

RESUMO

BACKGROUND: Endotracheal tube (ETT) tip position is determined on chest X-ray (CXR) and should lie between the upper border of the first thoracic vertebra (T1) and the lower border of second thoracic vertebra (T2). Infant weight is commonly used to estimate how far the ETT should be inserted but frequently results in malpositioned ETT tips. Palpation of the ETT tip at the suprasternal notch has been recommended as an alternative. OBJECTIVE: To determine whether estimating ETT insertion depth using suprasternal palpation of the ETT tip rather than weight results in more correctly positioned ETT tips. DESIGN: Single-centre randomised controlled trial. SETTING: Level III neonatal intensive care unit (NICU) at a university maternity hospital. PATIENTS: Newborn infants without congenital anomalies intubated in the NICU. INTERVENTIONS: Participants were randomised to have ETT insertion depth estimated using palpation of the ETT tip at the suprasternal notch or weight [insertion depth (cm)=6 + wt (kg)]. MAIN OUTCOME MEASURE: Correct ETT position, that is, between the upper border of T1 and lower border of T2 on CXR, determined by one consultant paediatric radiologist masked to group assignment. RESULTS: There was no difference in the proportion of correctly placed ETT tips between the groups (suprasternal palpation 27/58 (47%) vs weight 23/60 (38%), p=0.456). Most incorrectly positioned ETTs were too low (56/68 (82%)). CONCLUSION: Estimating ETT insertion depth using suprasternal palpation did not result in more correctly positioned ETTs. TRIAL REGISTRATION NUMBER: ISRCTN13570106.


Assuntos
Recém-Nascido Prematuro , Intubação Intratraqueal/métodos , Palpação/métodos , Feminino , Idade Gestacional , Hospitais Universitários , Humanos , Lactente Extremamente Prematuro , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Masculino , Palpação/normas
7.
J Matern Fetal Neonatal Med ; 33(14): 2354-2358, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30614319

RESUMO

Background: The accurate identification of an intervertebral lumbar level is essential to avoid neuraxial anesthesia and analgesia-related spinal cord injury. It has been shown that estimation of L3/4 intervertebral lumbar level based on the intercristal line determined by palpation (palpated L3/4) is often inaccurate. However; studies evaluating intervertebral lumbar level concordance based on palpation vs. ultrasonography were conducted in Western populations (i.e. in North America and/or Europe). Radiological studies suggest that the intercristal line intersects at a lower level of the spine in Japanese women than in Western women. Therefore, we hypothesized that differences exist in intervertebral levels based on the palpated intercristal line between Asian and Western women. Herein we present the results of the first study in Japan comparing the concordance rate of L3/4 intervertebral lumbar level estimated by palpation and ultrasonography in pregnant Japanese women.Study objective: The objective of this study was to evaluate the accuracy of palpated L3/4 in Japanese parturients assessed by ultrasonography (US).Design: A prospective, observer-blinded study.Setting: Labor and delivery room at the Kitasato University Hospital, Sagamihara, Kanagawa, Japan.Patients: Sixty-three term parturients underwent induction of labor and requested neuraxial labor analgesia.Interventions: With the patients in the sitting position, an attending anesthesiologist marked the intervertebral space estimated as L3/4 based on intercristal line with palpation. Another attending anesthesiologist who was blinded to the marker performed US to identify L3/4.Results: The overall agreement rate of palpated and US L3/4 was 69.8% (44/63). Palpated L3/4 was US L2/3 in 8/63 (12.7%) and US L4/5 in 11/63 (17.5%). In comparison with women with palpated L3/4 agreed with US L3/4, women with palpated L3/4 agreed with US L2/3 were more frequently multiparous (52 vs. 100%, p < .05) and women with palpated L3/4 identified as L4/5 were younger (36 ± 4 years vs. 33 ± 4 yrs, p < .05) and gained less weight during pregnancy (10 ± 4 kg vs. 7 ± 4 kg, p < .05). The patients whose palpated L3/4 were found to be US L2/3 were all multiparous.Conclusion: The accuracy rate of palpated L3/4 intervertebral lumbar level in pregnant women included in our study was 69.8%. Pregnancy-related weight gain, parity, and maternal age can all influence an estimation of L3/4 intervertebral lumbar level by palpation. In addition, we believe that this is the first study to analyze the correlation between maternal parity and interspace estimation by palpation in pregnant women.


Assuntos
Disco Intervertebral , Vértebras Lombares , Palpação/normas , Ultrassonografia/normas , Adulto , Analgesia Epidural/métodos , Analgesia Obstétrica/métodos , Feminino , Humanos , Disco Intervertebral/anatomia & histologia , Disco Intervertebral/diagnóstico por imagem , Japão , Vértebras Lombares/anatomia & histologia , Vértebras Lombares/diagnóstico por imagem , Gravidez , Estudos Prospectivos , Traumatismos da Medula Espinal/prevenção & controle
8.
BMC Med Educ ; 19(1): 177, 2019 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-31146715

RESUMO

BACKGROUND: In osteopathic medicine, palpation is considered to be the key skill to be acquired during training. Whether palpation skills are adequately acquired during undergraduate or postgraduate training is difficult to assess. The aim of our study was to test a palpation assessment tool developed for undergraduate medical education in a postgraduate medical education (PME) setting. METHODS: We modified and standardized an assessment tool, where a coin has to be palpated under different layers of copy paper. For every layer depth we randomized the hiding positions with a random generator. The task was to palpate the coin or to determine that no coin was hidden in the stack. We recruited three groups of participants: 22 physicians with no training in osteopathic medicine, 25 participants in a PME course of osteopathic techniques before and after a palpation training program, 31 physicians from an osteopathic expert group with at least 700 h of osteopathic skills training. These experts ran the test twice to check for test-retest-reliability. Inferential statistical analyzes were performed using generalized linear mixed models with the dichotomous variable "coin detected / not detected" as the dependent variable. RESULTS: We measured a test-retest reliability of the assessment tool as a whole with 56 stations in the expert group of 0.67 (p <  0.001). For different paper layers, we found good retest reliabilities up to 300 sheets. The control group detected a coin significantly better in a depth of 150 sheets (p = 0.01) than the pre-training group. The osteopathic training group showed significantly more correct coin localizations after the training in layer depths of 200 (p = 0.03) and 300 sheets (p = 0.05). This group also had significantly better palpation results than the expert group in the depth of 300 sheets (p = 0.001). When there was no coin hidden, the expert group showed significantly better results than the post-training group (p = 0.01). CONCLUSIONS: Our tool can be used with reliable results to test palpation course achievements with 200 and 300 sheets of paper. Further refinements of this tool will be needed to use it in complex assessment designs for the evaluation of more sophisticated palpatory skills in postgraduate medical settings.


Assuntos
Competência Clínica , Educação Médica Continuada/normas , Palpação , Adulto , Competência Clínica/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Palpação/métodos , Palpação/normas , Reprodutibilidade dos Testes
9.
Work ; 62(4): 647-656, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31104050

RESUMO

BACKGROUND: Clinical Breast Examination (CBE) is the examination of a women's breasts by a healthcare professional, such as a breast surgeon, family physician or breast-care nurse who is trained to recognise many different types of abnormalities and warning signs in the breast [1]. CBE is particularly important in rural areas and developing countries who have limited access to technology such as mammography. CBE needs to be taught to health professionals like any other clinical skill used by medical professionals in the workplace. CBE in part involves palpation of the breast, that is, determining by touch which breast lumps are normal and which are suspicious in feeling. The gold standard for assessing tactile skills in CBE is seeing whether students can accurately identify and discriminate between different breast lumps also known as masses (IDBM) on actual patients in a clinical setting. However, this is not practical in a medical education setting. Usually the testing methods 'go through the motions' of feeling the breast as part of CBE. So the students' technique is examined either using unrealistic simulation models or using an intimate examination associate (IEA), an actor/volunteer who permits students to examine their intimate body parts such as breast or genitals for teaching purposes. These volunteers do not have any abnormalities so this teaching does not include the actual detection of suspicious lumps. We undertook a study of clinical skill with 10 medical students to examine different methods of assessing novice student clinical skills after a brief training in CBE. OBJECTIVES: This study aims to evaluate the effectiveness of current training and assessment of novice students in CBE and their capacity to identify and discriminate breast masses (IDBM) on actual patients. METHODS: We assessed each student's IDBM ability in an actual clinical situation, a breast clinic with a mixture of eight IEAs and one real patient with a large, easily palpable, putative breast cancer. We recruited 10 clinically inexperienced medical students, who were trained for 30 minutes by two breast surgeons using an IEA. Students were tested in a simulated clinical setting, a breast clinic where each examined 4 IEAs and one patient. The students were blind to who was the real patient and who was an IEA. Patients were examined by a breast surgeon in private prior to the commencement in the study. The breast surgeon recorded any clinical finding on the patients during the initial examination. The surgeon coached each patient on how to mark the students and showed the patient their results so the patients had a benchmark. After each examination was finished the students had four different assessments: 1) patients marked each student, 2) students were independently proctored - that is, marked by an expert, 3) students recorded their clinical findings and 4) students recorded how confident they were that they had the correct findings. Results from different kinds of student assessments were compared.RESULTSA chi-square test for independence between true positive or negative masses versus student-assessed positive or negative masses was not significant at alpha = .05. This means that there was no statistical association in the indication of positive or negative presence of masses versus whether such masses were actually present or absent. By comparison, experts (breast surgeons) were able to detect normal and abnormal breast masses by palpation alone 100% of the time and rate their confidence level as 'certain'. Unlike the experts, student self-reported confidence was unrelated to their competence score (CS). Proctoring was inversely related to the students' CS.CONCLUSIONSThe main conclusion is that novice students do not seem to be able to accurately detect breast masses in a clinical setting even after training. On the basis of these results, we believe that a comprehension component in the current CBE testing is needed in addition to the current methods of testing.


Assuntos
Neoplasias da Mama/diagnóstico , Mama/anormalidades , Exame Físico/normas , Adulto , Mama/fisiopatologia , Distribuição de Qui-Quadrado , Competência Clínica/normas , Educação de Graduação em Medicina/métodos , Avaliação Educacional/métodos , Feminino , Humanos , Palpação/métodos , Palpação/normas , Exame Físico/métodos , Estudantes de Medicina/estatística & dados numéricos
10.
Br J Anaesth ; 123(3): 392-398, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30987766

RESUMO

BACKGROUND: Identification of the cricothyroid membrane is frequently inaccurate in females because of less distinct anatomy compared with males. Supraglottic airway devices cause ventral displacement of the laryngeal structures. We investigated if this would impact on the accuracy of cricothyroid membrane identification using palpation. METHODS: We recruited 64 adult females who underwent assessment by volunteer participants with and without a sited i-gel® supraglottic airway device. The primary outcome was accuracy in identifying the cricothyroid membrane. Secondary outcomes included distance from participant estimate to actual cricothyroid membrane location and perceived difficulty using a visual analogue scale. Ultrasound images were analysed to determine the effect of the i-gel® on the anatomical structures relevant to cricothyroidotomy. RESULTS: The cricothyroid membrane was identified correctly in 42/64 subjects with the i-gel® in place (66%) vs 23/64 of controls (36%; P<0.001, mean difference 30%; 95% confidence interval, 12-47%). VAS (P<0.001) and distance to the cricothyroid membrane (P<0.001) decreased in the intervention group. Analysis of the ultrasound image series showed a reduction in the mean angle between the cricothyroid membrane and anterior wall of the trachea in the i-gel® group, because of the more ventral position of the cricoid cartilage compared with control images (166° vs 151°, P<0.001). CONCLUSIONS: The presence of the i-gel® improved accuracy of identifying the cricothyroid membrane using palpation in females. The cricoid cartilage was pushed ventrally by the i-gel® in the hypopharynx, creating a more palpable prominence. It may therefore be advantageous to retain a sited supraglottic airway, rather than remove it, before performing emergency cricothyroidotomy.


Assuntos
Competência Clínica , Cartilagem Cricoide/anatomia & histologia , Máscaras Laríngeas , Palpação/normas , Cartilagem Tireóidea/anatomia & histologia , Adulto , Antropometria/métodos , Cartilagem Cricoide/diagnóstico por imagem , Feminino , Humanos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Intubação Intratraqueal/normas , Pessoa de Meia-Idade , Estudos Prospectivos , Cartilagem Tireóidea/diagnóstico por imagem , Ultrassonografia
11.
Simul Healthc ; 14(3): 201-207, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30969270

RESUMO

INTRODUCTION: There is still a need for competent breast lump detection palpation skills, especially in developing countries. Our goal is to design, develop, and establish a test to determine whether students can, by touch alone, identify and discriminate between a range of different simulated lesions at different adiposity levels. METHODS: Common lesions, breast cancers, and cysts were physically simulated and hidden in a test object referred to as the "tactile landscape" (TL). Ribs, intercostal muscle, and nodularity-normal anatomical features-increased their realistic complexity. Varying depths of features simulated varying degrees of adiposity. A testing protocol was created to determine the testee's ability to identify and discriminate different commonly occurring breast masses using palpation. Five experts (four breast surgeons and one general practitioner) and 20 inexperienced medical students were recruited and tested. Results were compared. RESULTS: The TL has been based on previously verified breast models and has softness similar to 53% of women's breasts and nodularity similar to 60% as assessed in a breast clinic by breast surgeons. The five experts indicated that the simulated lesions felt like those they might encounter in clinical practice and all of them identified the lesions and nonlesions hidden in the TL 100% correctly, thus indicating the value of the model. In contrast, only one student was able to identify all the lesions. One student identified none of them. The remaining students mean score was 65%. CONCLUSIONS: All students but one performed poorly in comparison to the experts. This indicates that the test could be useful to test students' ability to identify and discriminate breast masses. If successful, it will add previously missing capability to the mix of assessment instruments already used, thus potentially improving clinical breast examination training and assessment.


Assuntos
Neoplasias da Mama/diagnóstico , Educação Médica/métodos , Modelos Anatômicos , Palpação/métodos , Competência Clínica , Feminino , Humanos , Masculino , Palpação/normas , Projetos Piloto , Adulto Jovem
12.
Arch Dis Child Fetal Neonatal Ed ; 104(4): F440-F442, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30262463

RESUMO

BACKGROUND: NeoTapAdvancedSupport (NeoTapAS) is a mobile application, based on a screen tapping method that calculates the heart rate (HR). We aimed to evaluate the accuracy of NeoTapAS in reliably determining HR from auscultation in a high-fidelity simulated newborn resuscitation scenario. METHODS: Paediatric residents assessed HR by auscultation plus NeoTapAS in an asphyxiated term infant scenario and orally communicated the estimated HR. An external observer simultaneously documented the actual HR set in the manikin and the communicated HR. RESULTS: One hundred and sixty HR measurements were recorded. The agreement between communicated and set HR was good (Cohen's kappa 0.80, 95% CI 0.72 to 0.87; Bangdiwala's weighted agreement strength statistic 0.93). Bland-Altman plot showed a mean difference between communicated and set HR values of 1 beats per minute (bpm) (95% agreement limits -9 to 11 bpm). CONCLUSION: NeoTapAS showed a good accuracy in estimating HR and it could be an important resource in settings with limited availability of ECG monitor.


Assuntos
Auscultação Cardíaca/normas , Frequência Cardíaca , Triagem Neonatal/normas , Palpação/normas , Eletrocardiografia , Humanos , Recém-Nascido , Manequins , Reprodutibilidade dos Testes
13.
Eur J Anaesthesiol ; 36(3): 200-205, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30431501

RESUMO

BACKGROUND: The usefulness of ultrasound-guided techniques for radial arterial catheterisation has been well identified; however, its usefulness has not been completely evaluated in infants under 12 months of age, who are generally considered the most difficult group for arterial catheterisation. OBJECTIVE: We evaluated whether ultrasound guidance would improve success rates and reduce the number of attempts at radial arterial catheterisation in infants. DESIGN: A randomised, controlled and patient-blinded study. SETTING: Single-centre trial, study period from June 2016 to February 2017. PATIENTS: Seventy-four infants undergoing elective cardiac surgery. INTERVENTION: Patients were allocated randomly into either ultrasound-guided group (group US) or palpation-guided group (group P) (each n=37) according to the technique applied for radial arterial catheterisation. All arterial catheterisations were performed by one of two experienced anaesthesiologists based on group assignment and were recorded on video. MAIN OUTCOME MEASURES: The primary endpoint was the first-pass success. The number of attempts and total duration of the procedure until successful catheterisation were also analysed. RESULTS: The first-pass success rate was significantly higher in the group US than in the group P (68 vs. 38%, P = 0.019). In addition, fewer attempts were needed for successful catheterisation in the group US than in the group P (median 1 [IQR 1 to 2] vs. 2 [1 to 4], P = 0.023). However, the median [IQR] procedural time (s) until successful catheterisation in the two groups was not significantly different (102 [49 to 394] vs. 218 [73 to 600], P = 0.054). CONCLUSION: The current study demonstrated that the ultrasound-guided technique for radial arterial catheterisation in infants effectively improved first-pass success rate and also reduced the number of attempts required. TRIAL REGISTRATION: ClinicalTrials.gov NCT02795468.


Assuntos
Cateterismo Periférico/métodos , Palpação/métodos , Artéria Radial/diagnóstico por imagem , Artéria Radial/cirurgia , Ultrassonografia de Intervenção/métodos , Fatores Etários , Cateterismo Periférico/normas , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Palpação/normas , Método Simples-Cego , Ultrassonografia de Intervenção/normas
14.
Chiropr Man Therap ; 26: 49, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30524705

RESUMO

Background: Despite widespread use by manual therapists, there is little evidence regarding the reliability of thoracic spine static palpation to test for a manipulable lesion using stiffness or tenderness as diagnostic markers. We aimed to determine the interrater agreement of thoracic spine static palpation for segmental tenderness and stiffness and determine the effect of standardised training for examiners. The secondary aim was to explore expert consensus on the level of segmental tenderness required to locate a "manipulable lesion". Methods: Two experienced chiropractors used static palpation of thoracic vertebrae on two occasions (pragmatic and standardised approaches). Participants rated tenderness on an 11-point numerical pain rating scale (NPRS) and raters judged segmental stiffness based on their experience and perception of normal mobility with the requested outcomes of hypomobile or normal mobility. We calculated interrater agreement using percent agreement, Cohen's Kappa coefficients ( κ ) and prevalence-adjusted bias-adjusted Kappa coefficients (PABAK). In a preliminary study, an expert panel of 10 chiropractors took part in a Delphi process to identify the level of meaningful segmental tenderness required to locate a "manipulable lesion". Results: Thirty-six participants (20 female) were enrolled for the reliability study on the 13th March 2017. Mean (SD) age was 22.4 (3.4) years with an equal distribution of asymptomatic (n = 17) and symptomatic (n = 17) participants. Overall, the interrater agreement for spinal segmental stiffness had Kappa values indicating less than chance agreement [ κ range - 0.11, 0.53]. When adjusted for prevalence and bias, the PABAK ranged from slight to substantial agreement [0.12-0.76] with moderate or substantial agreement demonstrated at the majority of spinal levels (T1, T2 and T6 to T12). Generally, there was fair to substantial agreement for segmental tenderness [Kappa range 0.22-0.77]. Training did not significantly improve interrater agreement for stiffness or tenderness. The Delphi process indicated that an NPRS score of 2 out of 10 identified a potential "manipulable lesion". Conclusion: Static palpation was overall moderately reliable for the identification of segmental thoracic spine stiffness and tenderness, with tenderness demonstrating a higher reliability. Also, an increased agreement was found within the mid-thoracic spine. A brief training intervention failed to improve reliability.


Assuntos
Palpação/normas , Médicos/normas , Doenças Torácicas/diagnóstico , Vértebras Torácicas/fisiopatologia , Adolescente , Adulto , Quiroprática , Técnica Delfos , Feminino , Humanos , Masculino , Manipulações Musculoesqueléticas , Variações Dependentes do Observador , Palpação/métodos , Reprodutibilidade dos Testes , Doenças Torácicas/fisiopatologia , Doenças Torácicas/terapia , Adulto Jovem
15.
J Bodyw Mov Ther ; 22(2): 396-401, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29861241

RESUMO

INTRODUCTION: Accurate and reliable palpation is needed to identify anatomical landmarks as well as to assess motion and dysfunctions. Although different trials suggested that training might increase reliability of palpation, the poor dependability of the examined tests may show the need to review the teaching methods to improve palpatory accuracy? The aims of this study were: METHODS: 82 examiners with different years of experience were enrolled from AIMO institute. Two different type of training sessions were performed (individual and group training). A total of 5 training sessions were performed during 5 weeks and 5 different models with a similar BMI were used. A uni-variated statistical analysis was used to evaluate the main effect of type and number of trainings, a multi-variated analysis was used to verify cross-effects. RESULTS: Overall results show moderate reliability for the correct detection of the position of the heel lift (Random probability being 33%, GT = 58.6% and SIPS = 57.1%, both P-value < 0.001). No difference was shown between the types of training (p-value GT = 0.503, p-value PSIS = 1) and no overall improvement was shown after the first training (P-value(GT) = 0.25, P-value(PSIS) = 0.96). The professional group improved the reliability during the training sessions starting from substantial reliability and ended with an almost perfect reliability (P-value GT = 0.0029, P-Value PSIS<0.001). Whereas the 3rd 4th and 5th showed a decreased performance. CONCLUSIONS: Type of training sessions seems not to influence reliability of palpation accuracy. The improvement of reliability during the training sessions seems to be related to the experience of examiners, which plays an important role in reliability and the learning experience.


Assuntos
Medicina Osteopática/educação , Palpação/métodos , Palpação/normas , Avaliação Educacional , Feminino , Fêmur/anatomia & histologia , Calcanhar/anatomia & histologia , Humanos , Ílio/anatomia & histologia , Masculino , Simulação de Paciente , Reprodutibilidade dos Testes
16.
J Headache Pain ; 18(1): 97, 2017 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-28952052

RESUMO

BACKGROUND: Migraine patients usually report a high prevalence of neck pain preceding or during the migraine attack. A recent investigation of musculoskeletal dysfunctions in migraine patients concluded that neck pain is not simply a symptom of the migraine attack but corresponds to identifiable muscle and joint alterations. Particularly pain provocation using palpation of the joints in the upper cervical spine was significantly more prevalent in patients with migraine than in headache-free participants. METHODS: One hundred seventy-nine migraineurs (diagnosed according to IHS classification criteria version III beta) and 73 age- and gender-matched healthy controls were examined by a physiotherapist blinded towards the diagnosis, using a palpation technique over the upper cervical spine. The palpation combined oscillating movements and sustained pressure. FINDINGS: Using simple palpation of the upper cervical spine, migraine patients can be stratified into three groups: painfree (11%), local pain only (42%), and pain referred to the head during sustained pressure (47%). Combining both test components (palpation and sustained pressure) has a high sensitivity and specificity for migraine. CONCLUSIONS: The response to palpation of the upper cervical spine may indicate migraine subtypes. The presence of musculoskeletal dysfunctions of the upper cervical spine should be identified and treated to avoid ongoing nociceptive input into the trigeminocervical complex. TRIAL REGISTRATION: German Clinical Trial Register DRKS-ID: DRKS00009622 .


Assuntos
Vértebras Cervicais/fisiopatologia , Transtornos de Enxaqueca/classificação , Transtornos de Enxaqueca/diagnóstico , Músculos do Pescoço/fisiopatologia , Cervicalgia/diagnóstico , Palpação/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transtornos de Enxaqueca/complicações , Cervicalgia/etiologia , Palpação/normas , Sensibilidade e Especificidade
17.
J Bodyw Mov Ther ; 21(2): 240-245, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28532864

RESUMO

BACKGROUND: The sacroiliac joint (SIJ) has been implicated as a potential source of low back and buttock pain. Several types of motion palpation and pain provocation tests are used to evaluate SIJ dysfunction. OBJECTIVE: The purpose of this study was to investigate the relationship between motion palpation and pain provocation tests in assessment of SIJ problems. DESIGN: This study is Descriptive Correlation. METHODS: 50 patients between the ages of 20 and 65 participated. Four motion palpation tests (Sitting flexion, Standing flexion, Prone knee flexion, Gillet test) and three pain provocation tests (FABER, Posterior shear, Resisted abduction test) were examined. Chi-square analysis was used to assess the relationship between results of the individuals and composites of these two groups of tests. RESULTS: No significant relationship was found between these two groups of tests. CONCLUSIONS: It seems that motion palpation tests assess SIJ dysfunction and provocative tests assessed SIJ pain which do not appear to be related.


Assuntos
Dor Lombar/diagnóstico , Medição da Dor/métodos , Palpação/métodos , Modalidades de Fisioterapia/normas , Articulação Sacroilíaca/patologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor/normas , Palpação/normas , Amplitude de Movimento Articular , Método Simples-Cego , Adulto Jovem
18.
Ann Surg ; 266(6): 1069-1074, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-27655241

RESUMO

OBJECTIVE: Develop new performance evaluation standards for the clinical breast examination (CBE). SUMMARY BACKGROUND DATA: There are several, technical aspects of a proper CBE. Our recent work discovered a significant, linear relationship between palpation force and CBE accuracy. This article investigates the relationship between other technical aspects of the CBE and accuracy. METHODS: This performance assessment study involved data collection from physicians (n = 553) attending 3 different clinical meetings between 2013 and 2014: American Society of Breast Surgeons, American Academy of Family Physicians, and American College of Obstetricians and Gynecologists. Four, previously validated, sensor-enabled breast models were used for clinical skills assessment. Models A and B had solitary, superficial, 2 cm and 1 cm soft masses, respectively. Models C and D had solitary, deep, 2 cm hard and moderately firm masses, respectively. Finger movements (search technique) from 1137 CBE video recordings were independently classified by 2 observers. Final classifications were compared with CBE accuracy. RESULTS: Accuracy rates were model A = 99.6%, model B = 89.7%, model C = 75%, and model D = 60%. Final classification categories for search technique included rubbing movement, vertical movement, piano fingers, and other. Interrater reliability was (k = 0.79). Rubbing movement was 4 times more likely to yield an accurate assessment (odds ratio 3.81, P < 0.001) compared with vertical movement and piano fingers. Piano fingers had the highest failure rate (36.5%). Regression analysis of search pattern, search technique, palpation force, examination time, and 6 demographic variables, revealed that search technique independently and significantly affected CBE accuracy (P < 0.001). CONCLUSIONS: Our results support measurement and classification of CBE techniques and provide the foundation for a new paradigm in teaching and assessing hands-on clinical skills. The newly described piano fingers palpation technique was noted to have unusually high failure rates. Medical educators should be aware of the potential differences in effectiveness for various CBE techniques.


Assuntos
Neoplasias da Mama/diagnóstico , Competência Clínica , Palpação/métodos , Feminino , Dedos/fisiologia , Ginecologia , Humanos , Masculino , Movimento , Obstetrícia , Palpação/classificação , Palpação/normas , Médicos de Família , Cirurgiões
19.
J Am Coll Radiol ; 13(11S): e31-e42, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27814822

RESUMO

A palpable breast mass is one of the most common presenting features of breast carcinoma. However, the clinical features are frequently nonspecific. Imaging performed before biopsy is helpful in characterizing the nature of the mass. For women with clinically detected breast masses, the vast majority will require evaluation with ultrasound. Diagnostic mammography is the initial imaging modality of choice for women aged ≥ 40 years; ultrasound is typically necessary unless a definitively benign mass is identified as the etiology of the clinical finding. For evaluating women aged <30 years and women who are pregnant or lactating, ultrasound is used for initial evaluation. For women aged 30 to 39 years, either ultrasound or diagnostic mammography may be used for initial evaluation. MRI is rarely indicated to evaluate a clinically detected finding. Biopsy is indicated for masses with suspicious features. Short-term follow-up is a reasonable alternative to biopsy for solid masses with probably benign features suggesting fibroadenoma. Correlation between imaging and the clinical finding is essential. The ACR Appropriateness Criteria® are evidence-based guidelines for specific clinical conditions that are reviewed every 2 years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer-reviewed journals and the application of a well established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances in which evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/normas , Mamografia/normas , Oncologia/normas , Palpação/normas , Guias de Prática Clínica como Assunto , Radiologia/normas , Neoplasias da Mama/patologia , Medicina Baseada em Evidências , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos
20.
Anesthesiology ; 123(5): 1033-41, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26352376

RESUMO

BACKGROUND: Misidentification of the cricothyroid membrane in a "cannot intubate-cannot oxygenate" situation can lead to failures and serious complications. The authors hypothesized that preprocedure ultrasound-guided identification of the cricothyroid membrane would reduce complications associated with cricothyrotomy. METHODS: A group of 47 trainees were randomized to digital palpation (n = 23) and ultrasound (n = 24) groups. Cricothyrotomy was performed on human cadavers by using the Portex device (Smiths Medical, USA). Anatomical landmarks of cadavers were graded as follows: grade 1-easy = visual landmarks; 2-moderate = requires light palpation of landmarks; 3-difficult = requires deep palpation of landmarks; and 4-impossible = landmarks not palpable. Primary outcome was the complication rate as measured by the severity of injuries. Secondary outcomes were correct device placement, failure to cannulate, and insertion time. RESULTS: Ultrasound guidance significantly decreased the incidence of injuries to the larynx and trachea (digital palpation: 17 of 23 = 74% vs. ultrasound: 6 of 24 = 25%; relative risk, 2.88; 95% CI, 1.39 to 5.94; P = 0.001) and increased the probability of correct insertion by 5.6 times (P = 0.043) in cadavers with difficult and impossible landmark palpation (digital palpation 8.3% vs. ultrasound 46.7%). Injuries were found in 100% of the grades 3 to 4 (difficult-impossible landmark palpation) cadavers by digital palpation compared with only 33% by ultrasound (P < 0.001). The mean (SD) insertion time was significantly longer with ultrasound than with digital palpation (196.1 s [60.6 s] vs. 110.5 s [46.9 s]; P < 0.001). CONCLUSION: Preprocedure ultrasound guidance in cadavers with poorly defined neck anatomy significantly reduces complications and improves correct insertion of the airway device in the cricothyroid membrane.


Assuntos
Anestesia/normas , Cartilagem Cricoide/diagnóstico por imagem , Intubação/normas , Pescoço/diagnóstico por imagem , Cartilagem Tireóidea/diagnóstico por imagem , Ultrassonografia de Intervenção/normas , Anestesia/métodos , Cadáver , Cartilagem Cricoide/cirurgia , Feminino , Humanos , Internato e Residência/métodos , Internato e Residência/normas , Intubação/métodos , Masculino , Pescoço/anatomia & histologia , Palpação/métodos , Palpação/normas , Cartilagem Tireóidea/cirurgia , Ultrassonografia de Intervenção/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...